Job-site sizing

Air scrubber sizing calculator

Enter the work area and your target air changes per hour. The calculator returns the airflow you need and how many units of a given size to set up, after a realistic allowance for filter and duct losses.

Airflow calculator

Not sure what target to use? See recommended air changes per hour by room type.

—
Room volume
—
Effective airflow
—
Air changes per hour
—
99% of particles removed in
—
99.9% removed in
—
Method

How to size air scrubbers for a job

  1. Measure the space you will treat — the containment, not the whole building. Volume is length × width × ceiling height.
  2. Pick a target ACH. Negative-pressure containments are commonly run at a minimum of 4 air changes per hour, a figure inherited from asbestos abatement practice; many remediators target 6 or more for mold and heavy dust. Fire and smoke odor work often runs higher still. See targets by job type.
  3. Derate the rated CFM. Manufacturer ratings are usually free-air with fresh filters. Loaded HEPA filters and lay-flat duct can take 20–30% off.
  4. Round up, not down. If the math says 1.3 units, you need 2 — or a bigger unit.
Worked example

A 20 × 15 ft basement with an 8 ft ceiling is 2,400 ft³. At 6 ACH it needs 6 × 2,400 ÷ 60 = 240 CFM of effective airflow. One 500 CFM scrubber derated by 20% delivers 400 CFM, or 10 ACH — comfortably enough.

The same target in a 60 × 40 ft warehouse bay with a 12 ft ceiling (28,800 ft³) needs 2,880 CFM: eight 500-CFM units, or four 1,000-CFM units.

Containment

Negative pressure

When a scrubber exhausts outside the containment it becomes a negative air machine: it pulls more air out than leaks in, so contaminated air does not escape to the rest of the building. A differential of about −0.02 inches of water column (−5 Pa) is the figure most commonly cited. The ACH you calculate here is the exhaust airflow through the containment — tighter enclosures reach the target pressure with less airflow, leaky ones need more. More on the difference.

Reference

Size classes

Rated airflowTypical useNotes
300–550 CFMSingle rooms, small containments, crawlspace sectionsLight, often stackable; easy to carry upstairs.
600–1,000 CFMThe restoration workhorse: bedrooms to open-plan floorsMost common class for mold and water jobs.
1,000–2,000 CFMLarge containments, commercial and construction dust controlHeavier; check the circuit amperage before running several.

What to compare when buying

  • Filtration stages — pre-filter, intermediate, and a true HEPA final filter (99.97% at 0.3 µm). Add carbon for odor.
  • Variable speed — lets one unit run quietly as a scrubber or at full power for negative air.
  • Ducting collar — needed for negative air setups; check the diameter matches your duct.
  • Amp draw — several units on one 15 A circuit is a common job-site trip.
  • Filter cost — the HEPA filter is the running cost; price replacements before buying the unit.

Compare HEPA air scrubbers

Affiliate link. We may earn a commission; calculator results are not affected.

These are planning estimates. For regulated work — asbestos, lead, healthcare construction — follow the required standard and your project specification, and verify pressure differential with a manometer.